power on after ac loss

Home Forums Quantum Access power on after ac loss

  • Author
    Posts
  • #21949

    tom12345
    Participant

    is there a setting or method to which this stick can power on by itself after ac power loss.

  • #21950

    Azulle Support Team
    Keymaster

    Hello tom12345,

    Thank you for using our Forums. The setting for Auto Power on is located in the BIOS (use DEL or ESC to get access to the BIOS) -> Advanced -> OS/BOM Configuration -> Select Auto Power on or manual power.

    Turn off your unit, then turn it back on and continuously press the ESC key until a blue screen pops out (BIOS). First make sure that you have the option on the BIOS. This feature will be located in the BIOS -> Advanced -> OS/BOM Configuration -> Select Auto Power on or manual power.

    If you do have the option Just select Auto Power on or manual power and then select Save & Exit, turn off the unit by removing the power cable then plug the cable back once again and if it turns on by itself then it worked.

    If you do NOT have the Auto Power on or manual power option on the BIOS then:

    Refer to this video on steps on how to update the BIOS https://www.youtube.com/watch?v=47jUn5EmphA

    Download the file required here: ftp://ftp.azulletech.com/Software/BIOS/Quantum%20Access/QA_QAL_432.zip

    Best regards.

You must be logged in to reply to this topic.

Login here

Register here